What is an arc flash?

An arc flash is one of the most destructive electrical faults possible to have. Not only will it cause tremendous damage to equipment, but could also give life changing and even life-threatening injuries to any personnel within a close proximity.

PPE is essential in helping to protect employees against arc flashes. Reputable arc flash PPE suppliers, such as Tower Supplies will ensure your employees have the level of protection they need.

What is the NFPA 70E and where does it apply?

The NFPA 70E addresses employee workplace electrical safety requirements.

It defines work practices that protect workers from electrical hazards, including arc flashes, during the inspection, operation and maintenance of electrical equipment.
The NFPA 70E standard covers most workplace activities related to electrical energy or equipment.

The major exceptions are:

  • Vehicles; such as ships, aircraft and railways
  • Communications equipment under the exclusive control of communications utilities.
  • Certain electrical installations under the exclusive control of an electric utility.
How to calculate arc flash rating

As part of NFPA 70E, an arc flash hazard analysis should be done in order to protect personnel from the possibility of being injured by an arc flash.
There are two distinct mathematical methods of calculating the available arc flash energy present at a specific piece of equipment.

Why do I need an arc protection system?

8 to 10 arc flashes occur in the UK every week. Without arc protection in place, the consequences can be very serious.
 
What does an arc protection system look like?

You only need three components to create a reliable arc protection system:

  • a protection relay
  • a series of arc flash detection sensors
  • an arc quenching device

Why do I need arc protection?

There are many benefits to fitting arc fault protection:

  • Damage limitation – Due to an ultra-fast tripping time of 2ms and quenching time of just 3ms, total destruction on the switchgear is prevented and is limited to only one section. This saves a great deal of downtime, because it won’t be necessary to wait for a whole board to be rebuilt. Selective tripping is also an option, meaning only the circuit breaker closest to the fault will trip. This can also assist in finding the source of the fault during investigation.
  • Cost-savings – There are many costs to consider in the aftermath of an arc fault. This includes an expensive rebuild of the switchgear, along with the repair of any other damage done to the room and the labour costs for doing so. Other costs often not considered are those when a staff member is injured (or worse) in the blast. This may involve legal fees, fines and compensation.


Related products
Product name
Arc Flash Detection
Arcteq's arc flash detection system consists of an arc flash relay, detection sensors and an arc quencher, offering both detection and the 'cure' to arc faults.

Find out more in the catalogue


Contact your local ComAp representative

Didn't find what you were looking for? Contact us, we’ll be happy to answer any questions you may have and help you with your business needs.

Interested in another country? Find your local representative

Our website uses cookies and similar technologies to provide you the best experience and to understand how you use our site.

You may either „Accept all“ by which you agree with using functional, analytical and marketing cookies. By pressing „Revoke“ only necessary cookies shall be allowed to enable the website and applications function correctly.. To revoke your consent you can do it from footer menu in Change cookie preferences section.

You can find more information on the Cookie page and the Privacy section .